BETA / TESTING VERSION: results ARE inaccurate. Verify everything independently. Not for construction.
🗺 Plot Layout: Rect
🏗️ Geometry: 3×5m · 3×5m · 4 floors
Typical floors: 3 (= total − basements)
📐 Vertical elements Axes
▬ Slab: Solid 20cm
Use different slab types for different floors
TOR slab Solid (fixed) Solid
Roof slab Solid Flat PT - Monolithic pour (Up to SDC F*; Check code cdts) PT - Strip (Up to SDC F*; Check code cdts) PT - Sliding joint (Up to SDC B*; Check code cdts) Ribbed Waffle Prestressed Prefab
Typical slab Solid Flat PT - Monolithic pour (Up to SDC F*; Check code cdts) PT - Strip (Up to SDC F*; Check code cdts) PT - Sliding joint (Up to SDC B*; Check code cdts) Ribbed Waffle Prestressed Prefab
Ground floor slab Solid Flat PT - Monolithic pour (Up to SDC F*; Check code cdts) PT - Strip (Up to SDC F*; Check code cdts) PT - Sliding joint (Up to SDC B*; Check code cdts) Ribbed Waffle Prestressed Prefab
Basement slab Solid Flat PT - Monolithic pour (Up to SDC F*; Check code cdts) PT - Strip (Up to SDC F*; Check code cdts) PT - Sliding joint (Up to SDC B*; Check code cdts) Ribbed Waffle Prestressed Prefab
Drives the slab concrete quantities and per-level checks. Ribbed / waffle levels carry one slider (overall depth); topping = overall depth - hourdis block. TOR and ramp slabs are always solid. Flat-slab levels carry no beams. Ribbed: hourdis blocks (box below) between ribs; total depth = block + topping. Unticked: every level uses the single slab type chosen below.
╦ Beams: Rectangular
▫ Generic beam sections
Separate edge beam section
Define a different section for perimeter (edge) beams vs. internal beams. When off, edge beams use the same section as internal beams above, sized for half the tributary load.
Separate X / Y beam sections (internal & external)
Four independent sections: Internal X = main section above; External X = the edge-beam section above (Internal X when that is off); Internal Y and External Y below. X beams run along the front-span axis, Y beams along the side-span axis. A beam is external when only one slab cell frames into it.
Internal beams — Y direction
Same as internal X Rectangular T-Beam IPE Steel None (no beam)
External beams — Y direction
Same as internal Y Same as external X Rectangular T-Beam IPE Steel None (no beam)
▐ Columns: Rectangular
Zone breakpoints (floor) Lower 1–2 · Mid 3–3 · Upper 4–4
Lower Middle 1 Upper
▫ Generic column sections
⊞ Corewalls, Shearwalls, BasementWalls: 4 walls · 25cm × 3m
▫ Corewalls
▫ Shearwalls
Length: X-walls = front bay width, Y-walls = side bay width
▫ BasementWalls
▫ Steel lateral systems (bracing & alternatives to core walls)
⚙ Propose system ↳ Apply R / Cd to model
Raft 60cm
Soil Type Presets
🟤 Very Soft Clay50 kPa
🟤 Soft Clay75 kPa
🟡 Medium Clay100 kPa
🟡 Stiff Clay/Sand150 kPa
🟠 Med-Dense Sand200 kPa
🟠 Dense Sand250 kPa
⚪ Dense Gravel300 kPa
⚪ Weathered Rock400 kPa
🪨 Soft Rock500 kPa
🪨 Hard Rock600 kPa
Medium Sand / Stiff Clay — Moderate to good bearing capacity. Suitable for shallow foundations. (200 kPa)
Medium Dense Sand — q_allow=200 kPa
ks = 40,000 kN/m³ — Medium Dense Sand / Stiff Clay (Vesic/Bowles)
Basement Wall — Earth Pressure
Typical ranges for the selected soil type — verify with the geotechnical report.
At-rest (K0 ) — wall propped by slabs (default)
Active (Ka ) — wall free to yield
Basement wall thickness (mm) 300
200 350 500 650 800
Used for the wall geometry, quantities, stiffness and the earth-pressure check.
Seismic earth-pressure increment (Wood / Seed–Whitman)
Ground level = top of the basement wall. Water: 15 m = none. Results in the Report tab → Basement Wall.
Typical tolerable total settlement (ASCE 7 / Bowles, Table 5.6): isolated footings ≤25mm, rafts/mats ≤50–75mm, range 5–150mm covers rigid steel frames to flexible mat foundations on compressible soils. Verify against project geotechnical report.
Raft spring = ks×A_trib. Δs limit L/500 (EN 1997).
Tie Beams (Isolated Found.)
Include tie beams in foundation
Tie beams drawn in plot layout. Designed for 10% of column axial load (ACI §15.8.3.3).
🧱 Materials: Reinforced Concrete
📐 Building Code: ASCE 7-22
⚖ Loads: SDL Light 1.5 · LL Residential 1.92 kN/m²
Superimposed Dead (SDL)
Live Load (kN/m²)
Include live load in the seismic weight (ASCE 0.25 × LL, Eurocode ψE × LL)
Basement ramp
Ramp vehicular live load (kN/m²) 2.5
0 2 4 6 8 10 12
2 kN/m² cars (ASCE garage 1.9) · 2.5 kN/m² EN 1991-1-1 cat. F · 5 kN/m² cat. G / light trucks · 12 kN/m² fire-truck / HGV access
Enable separate roof loads
Roof loads override typical floor loads on the top level only (ASCE 7-22 §4.8 / §7)
Roof SDL
Roof Live Load
Snow Load (if applicable)
⚙ Advanced Settings
🌍 Site: Dubai · C · Ss=0.20g
📍 City / Region Dubai (UAE)
— Select city —
Abu Dhabi (UAE)
Amman (Jordan)
Antakya (Turkey)
Athens (Greece)
Baghdad (Iraq)
Barcelona (Spain)
Beirut (Lebanon)
Berlin (Germany)
Cairo (Egypt)
Damascus (Syria)
Dammam (Saudi Arabia)
Doha (Qatar)
Dubai (UAE)
Erbil (Iraq)
Florence (Italy)
Fujairah (UAE)
Geneva (Switzerland)
Istanbul (Turkey)
Jeddah (Saudi Arabia)
Kuwait City (Kuwait)
Lisbon (Portugal)
London (UK)
Madrid (Spain)
Manama (Bahrain)
Munich (Germany)
Muscat (Oman)
Paris (France)
Riyadh (Saudi Arabia)
Rome (Italy)
Sharjah (UAE)
Tehran (Iran)
User defined values…
Ss=0.20g · S₁=0.07g · Wind=38 m/s · Exp C — Dubai (UAE)
Importance Class (EN 1998-1 §4.2.5)
Risk Category: Typical
Based on the above inputs, the SDC is: —
Max allowable height (current SDC & system): —
Seismic System — RC Intermediate MRF : R=5, Cd=4.5
Behavior Factor q (EN 1998-1 §5.2.2/Table 6.2)
Design spectrum ordinate Sd(T) = ag·S·(2.5/q)·η for T1≤T≤TC (EN 1998-1 Eq.3.13), with a lower bound of β·ag = 0.2·ag.
Exposure & Concrete Cover: XC1 · Normal
Wind: 35 m/s · Exp B
Seismic base (basement mass)
Auto — grade if basement is rigid
Foundation — include basement mass
Grade — GF slab (rigid basement)
Base at the foundation (no basement).
🔬 Serviceability & Durability
⚡ Initial Value EngineeringSlabs, beams, columns & foundations — smallest sizes that still pass their D/C checks
Also optimize seismic system R (manual run)
Auto-assign on input change (Pre-Model only)
⚡ Final Value EngineeringSlabs, beams, columns & foundations — smallest sizes that still pass their D/C checks
☰ Inputs
☰ Results
▁ Minimize
⧉
–
Internal Beam Moment X — Multi-span Frame
–
Internal Beam Moment Y — Multi-span Frame
▲ ▼ ◫ 2D Viewport
D/C
⧉ Extrude
⟳ 3D
⌂ Found.
⊟ Bsmt
⊟ Typ. Slab
🏠 Roof
⊡ Reset
✏ Edit Layout
✓ Apply & Close
🏠 Edit Roof
✓ Apply Roof
✏ EDIT
⬡ Select
✕ Delete
+ Col
+ Slab
✎ Beam
✎ SW
⚖ Load
⤢ Axis
↩ Undo
⊡ Reset
Switch to Slab Plan · pick a tool · click elements
🏠 ROOF ONLY — changes do not affect typical floors
⧉
– Foundation X — Multi-span Internal Strip Moment
– Foundation Y — Multi-span Internal Strip Moment
Shop Drawing
Shop drawings are not generated in XSD yet. This tab is reserved for the reinforcement shop drawings (plans, elevations, sections, bar marks and shapes) drawn from the design.